Freshly certified fume hood with a compliance label in an Alberta laboratory
Home/Fume Hood Certification/Annual Compliance Certification
Fume Hood Certification

Annual Regulatory Compliance Certification

The yearly check that keeps your hoods compliant and your audits clean. We test each hood, label it, and hand you a report that lines up with OSHA and ANSI/AIHA Z9.5.

Every lab manager knows the feeling: the audit is coming and half the hoods are past due. Annual certification is the routine that stops that scramble. Test once a year, keep the labels current, and the paperwork is ready before anyone asks.

Clean Mott fume hood awaiting annual compliance certification

Annual compliance certification is a yearly inspection and test of each fume hood to confirm it still contains and still meets the standards your safety office answers to. It is the baseline every chemical fume hood needs, and it is the one most auditors look for first.

What the annual certification includes

  • Face-velocity profiling to confirm the airflow is in the safe range.
  • Smoke visualization to see how the air actually moves and catch reverse flow.
  • Sash, baffle, and alarm checks to confirm the hood's parts work.
  • A dated certification label on the hood and a written report for your files.
Alberta reminder: winter makeup air can pull a hood out of range between annual checks. If your building runs tight on heating air, a mid-winter spot check is cheap insurance.

Built for audits

Your report names the standards each hood was tested against, shows the data, and gives auditors a clean trail. For campus buildings and multi-hood sites, we schedule the whole set together so nothing slips past its due date, and we track when each hood is next due.

When a hood does not pass

We do not just flag a failure and leave. We tell you the cause in plain language and help you fix it, then re-certify once it is sorted. If the issue is room airflow rather than the hood itself, our VAV and CAV air balancing team can rebalance it. For hoods that need hard containment proof, we can step up to full ASHRAE 110 testing.

Good Questions

Frequently asked questions

Once a year is the standard for most hoods, which keeps you compliant with OSHA and ANSI/AIHA Z9.5. High-use, ductless, or high-hazard hoods may need it every six months, and any hood that was moved should be re-certified before it goes back into service.

The label shows the date it was certified and when it is next due, right on the hood so users and auditors can see it at a glance. The detailed test data lives in the written report we give you.

Yes. For multi-hood labs and campus buildings we schedule the whole set together and track the due dates, so you are not chasing individual hoods through the year.

Not quite. Annual certification usually covers face velocity, smoke, and a parts check, which is enough for most hoods. ASHRAE 110 is a deeper tracer-gas test for containment, worth adding for new installs, moves, or high-hazard work.

Not sure where to start? Just ask.

Describe what is in your lab and we will tell you what testing or cleanup makes sense, with no obligation.

Book a Site Assessment